What changed between revision 4 and revision 5, compared over the article's markdown source with its frontmatter — so a change to status, evidence or reversibility shows up as the edit it is.
Older · revision 4
Import
Re-import of content/brain-computer-interface.md — the file changed after the initial import. Not an edit.
20.3 kB
Revision 4
Revision 5
lines 8–14 → 8–147 unchanged lines not shown
categories: ["cybernetics", "foundations"]categories: ["cybernetics", "foundations"]tags: ["bci", "neurotechnology", "paralysis", "neural decoding", "implants", "assistive technology"]tags: ["bci", "neurotechnology", "paralysis", "neural decoding", "implants", "assistive technology"]summary: "A system that measures nervous-system activity, decodes an intention or state from it, and converts that decoded signal into a command for an external device."summary: "A system that measures nervous-system activity, decodes an intention or state from it, and converts that decoded signal into a command for an external device."updated: "2026-10-28"updated: "2026-10-29"humanEvidence: "Implanted arrays have given research participants with paralysis cursor control, robotic-arm use and conversational-rate speech decoding; no implanted BCI has been shown to improve any capability in a healthy person."humanEvidence: "Implanted arrays have given research participants with paralysis cursor control, robotic-arm use and conversational-rate speech decoding; no implanted BCI has been shown to improve any capability in a healthy person."access: "No implanted BCI is approved by any regulator; the only route is enrolment in an early feasibility trial. Consumer EEG headsets are sold freely as wellness devices."access: "No implanted BCI is approved by any regulator; the only route is enrolment in an early feasibility trial. Consumer EEG headsets are sold freely as wellness devices."reversibility: "difficult"reversibility: "difficult"lines 29–48 → 29–4814 unchanged lines not shown
}}`````` **Brain–computer interface** (BCI) is the general term for a system that measures activity in the**Brain-computer interface** (BCI) is the general term for a system that measures activity in thenervous system, extracts a variable of interest from that activity, and turns it into a command fornervous system, extracts a variable of interest from that activity, and turns it into a command fora computer, a prosthesis, or the person's own muscles. The defining feature, in the standarda computer, a prosthesis, or the person's own muscles. The defining feature, in the standardformulation, is that the command bypasses the ordinary output path of peripheral nerve andformulation, is that the command bypasses the ordinary output path of peripheral nerve andmuscle.[^wolpaw2002] A BCI is therefore useful mainly to peoplemuscle.[^wolpaw2002] A BCI is therefore useful mainly to people whose ordinary output path iswhose ordinary output path is broken, and as of 2026 every serious clinical result comes from thatbroken, and as of 2026 every serious clinical result comes from that population: participants withpopulation: participants with tetraplegia, brainstem stroke, or amyotrophic lateral sclerosis.tetraplegia, brainstem stroke, or amyotrophic lateral sclerosis. The field has produced genuinely striking demonstrations — a person with no usable movementThe field has produced striking demonstrations in a very small number of research participants: acontrolling a robotic arm, another producing fluent synthesized speech from motor-cortex activityperson with no usable movement controlling a robotic arm, another producing fluent synthesizedalone — in a very small number of research participants, using hardware that is tethered, requiresspeech from motor-cortex activity alone. The hardware behind them is tethered, requires frequentfrequent recalibration, and has not been approved by any regulator for permanent use. The gaprecalibration, and has not been approved by any regulator for permanent use. The gap between thosebetween those demonstrations and a product is largely a gap in reliability, longevity, anddemonstrations and a product lies largely in reliability, longevity, and manufacturing rather thanmanufacturing, not in principle.in principle. ```figure```figure{"key": "braingate-array", "caption": "The implanted array against a human hand. The entire recording surface is a few millimetres square."}{"key": "braingate-array", "caption": "The implanted array against a human hand. The entire recording surface is a few millimetres square."}lines 50–75 → 50–761 unchanged line not shown
## The signal chain## The signal chain Every BCI is the same four stages: acquisition, feature extraction, decoding, and output, usuallyEvery BCI has the same four stages: acquisition, feature extraction, decoding, and output, usuallywith a feedback loop closing back to the user.with a feedback loop closing back to the user. *Acquisition* determines everything downstream. Signals differ by how close the sensor sits to the*Acquisition* determines everything downstream. Signals differ by how close the sensor sits to theneurons producing them. Penetrating microelectrodes recording action potentials from individualneurons producing them. Penetrating microelectrodes recording action potentials from individualcells carry the most information per channel; scalp electroencephalography, separated from cortexcells carry the most information per channel; scalp electroencephalography, separated from cortex byby dura, skull, and scalp, carries the least, because the skull acts as a spatial low-pass filterdura, skull, and scalp, carries the least, because the skull acts as a spatial low-pass filter thatthat smears contributions from many square centimetres of cortex into one measurement.smears contributions from many square centimetres of cortex into one measurement. *Feature extraction* reduces raw voltage into something a decoder can use: firing rates binned over*Feature extraction* reduces raw voltage into something a decoder can use: firing rates binned overtens of milliseconds, power in a frequency band, the amplitude of an evoked potential. In corticaltens of milliseconds, power in a frequency band, the amplitude of an evoked potential. In corticalrecordings the workhorse features are threshold crossings and high-gamma power (roughly 70–200 Hz),recordings the workhorse features are threshold crossings and high-gamma power (roughly 70-200 Hz),the latter being a reasonable proxy for local population spiking that can be measured withoutthe latter being a reasonable proxy for local population spiking that can be measured withoutpenetrating the cortex.penetrating the cortex. *Decoding* maps features to intent. Early systems used linear filters and the population-vector*Decoding* maps features to intent. Early systems used linear filters and the population-vectorapproach inherited from primate motor physiology; current systems use Kalman filters, recurrentapproach inherited from primate motor physiology; current systems use Kalman filters, recurrentneural networks, and increasingly transformer-style sequence models paired with [language models](https://aiwiki.ai/wiki/large_language_model).neural networks, and increasingly transformer-style sequence models paired with [language[[neural-decoding]] is where most of the recent performance gains have come from — the electrodesmodels](https://aiwiki.ai/wiki/large_language_model). Most of the recent performance gains have comein the best 2025 speech systems are not fundamentally better than those used in 2012.from [[neural-decoding]]; the electrodes in the best 2025 speech systems are not fundamentallybetter than those used in 2012. *Output* is a cursor, a robotic arm, a synthesized voice, a wheelchair, or stimulation delivered to*Output* is a cursor, a robotic arm, a synthesized voice, a wheelchair, or stimulation delivered tothe user's own spinal cord or to a powered [[exoskeleton]]. Bidirectional systems also writethe user's own spinal cord or to a powered [[exoskeleton]]. Bidirectional systems also writelines 82–98 → 83–1026 unchanged lines not shown
a character grid and detects the evoked response that follows an attended flash; steady-statea character grid and detects the evoked response that follows an attended flash; steady-statevisually evoked potential systems tag each option with a distinct flicker frequency and read offvisually evoked potential systems tag each option with a distinct flicker frequency and read offwhich frequency dominates visual cortex; sensorimotor-rhythm systems ask the user to imaginewhich frequency dominates visual cortex; sensorimotor-rhythm systems ask the user to imaginemovement of a limb and detect the resulting suppression of mu and beta rhythms. All three work.movement of a limb and detect the resulting suppression of mu and beta rhythms. All three work, butNone is fast: information transfer rates are conventionally reported in the range of tens of bitsnone is fast: information transfer rates are conventionally reported in the range of tens of bitsper minute, on the order of a few characters, against several hundred bits per minute for competentper minute, on the order of a few characters, against several hundred bits per minute for competenttyping.typing. Functional near-infrared spectroscopy and functional MRI measure haemodynamics rather thanFunctional near-infrared spectroscopy and functional MRI measure haemodynamics rather thanelectrical activity, and are therefore limited by the seconds-long delay of the blood-oxygenelectrical activity, and are therefore limited by the seconds-long delay of the blood-oxygenresponse. fMRI remains valuable for decoding research precisely because it covers the whole brain,response. fMRI remains valuable for decoding research because it covers the whole brain, but abut a scanner is not a wearable device. Time-domain fNIRS, which times returning photons to gain depth sensitivity, has been built into a whole-head wearable helmet by [[kernel]], whose first-generation Kernel Flow weighed about 2 kg and was benchmarked mainly on optical phantoms and a two-person finger-tapping task.[^ban2022] Kernel sells it for research and brain-health measurement rather than for device control. Consumer EEG headsets sit at the weakest endscanner is not a wearable device. Time-domain fNIRS, which times returning photons to gain depthof the spectrum, typically with a handful of dry electrodes and heavy artefact contamination fromsensitivity, has been built into a whole-head wearable helmet by [[kernel]], whose first-generationeye movement and jaw muscle.Kernel Flow weighed about 2 kg and was benchmarked mainly on optical phantoms and a two-personfinger-tapping task.[^ban2022] Kernel sells it for research and brain-health measurement rather thanfor device control. Consumer EEG headsets sit at the weakest end of the spectrum, typically with ahandful of dry electrodes and heavy artefact contamination from eye movement and jaw muscle. ```compare```compare{{lines 100–106 → 104–1101 unchanged line not shown
"rows": [ "rows": [ { "label": "Surgery", "values": ["Craniotomy, cortical penetration", "Craniotomy or slot", "Catheter via jugular vein", "None"] }, { "label": "Surgery", "values": ["Craniotomy, cortical penetration", "Craniotomy or slot", "Catheter via jugular vein", "None"] }, { "label": "Resolution", "values": ["Single neurons", "Millimetre populations", "Coarse populations", "Centimetre populations"] }, { "label": "Resolution", "values": ["Single neurons", "Millimetre populations", "Coarse populations", "Centimetre populations"] }, { "label": "Typical channels", "values": ["96–1,024", "64–1,024", "16", "8–256"] }, { "label": "Typical channels", "values": ["96-1,024", "64-1,024", "16", "8-256"] }, { "label": "Long-term stability", "values": ["Degrades over months to years", "Good over years", "Good over years", "Good, but user-dependent"] }, { "label": "Long-term stability", "values": ["Degrades over months to years", "Good over years", "Good over years", "Good, but user-dependent"] }, { "label": "Demonstrated ceiling", "values": ["Multi-degree-of-freedom limb control, fluent speech", "Fluent speech, walking via spinal stimulation", "Discrete clicks", "Spellers, simple switches"] } { "label": "Demonstrated ceiling", "values": ["Multi-degree-of-freedom limb control, fluent speech", "Fluent speech, walking via spinal stimulation", "Discrete clicks", "Spellers, simple switches"] } ] ]lines 119–131 → 123–13512 unchanged lines not shown
[[ { "year": "1924", "title": "Human EEG recorded", "text": "Hans Berger records electrical rhythms from the human scalp, establishing that cortical activity can be measured non-invasively." }, { "year": "1924", "title": "Human EEG recorded", "text": "Hans Berger records electrical rhythms from the human scalp, establishing that cortical activity can be measured non-invasively." }, { "year": "1973", "title": "The term is coined", "text": "Jacques Vidal at UCLA publishes 'Toward direct brain-computer communication', proposing that computers could interpret EEG in real time as control signals." }, { "year": "1973", "title": "The term is coined", "text": "Jacques Vidal at UCLA publishes 'Toward direct brain-computer communication', proposing that computers could interpret EEG in real time as control signals." }, { "year": "1999–2002", "title": "Motor decoding in animals", "text": "Groups led by John Chapin, Miguel Nicolelis, and Andrew Schwartz show that rats and monkeys can control levers and robotic arms using decoded cortical ensemble activity." }, { "year": "1999-2002", "title": "Motor decoding in animals", "text": "Groups led by John Chapin, Miguel Nicolelis, and Andrew Schwartz show that rats and monkeys can control levers and robotic arms using decoded cortical ensemble activity." }, { "year": "2004–2006", "title": "First long-term human implant", "text": "Matthew Nagle, paralysed by a spinal cord injury, receives a Utah array in the BrainGate pilot and controls a cursor, a television, and a prosthetic hand." }, { "year": "2004-2006", "title": "First long-term human implant", "text": "Matthew Nagle, paralysed by a spinal cord injury, receives a Utah array in the BrainGate pilot and controls a cursor, a television, and a prosthetic hand." }, { "year": "2012–2013", "title": "Robotic arm control", "text": "BrainGate and University of Pittsburgh teams report multi-degree-of-freedom robotic arm control by participants with tetraplegia, including self-feeding." }, { "year": "2012-2013", "title": "Robotic arm control", "text": "BrainGate and University of Pittsburgh teams report multi-degree-of-freedom robotic arm control by participants with tetraplegia, including self-feeding." }, { "year": "2016", "title": "Fully implanted communication BCI", "text": "A Utrecht group implants a wireless electrocorticography system in a person with late-stage ALS, who uses it at home for years to select letters." }, { "year": "2016", "title": "Fully implanted communication BCI", "text": "A Utrecht group implants a wireless electrocorticography system in a person with late-stage ALS, who uses it at home for years to select letters." }, { "year": "2021–2024", "title": "Speech decoding becomes fluent", "text": "UCSF, Stanford, and UC Davis teams decode attempted speech at conversational rates from motor cortex, with large vocabularies and single-digit word error rates in the best case." }, { "year": "2021-2024", "title": "Speech decoding becomes fluent", "text": "UCSF, Stanford, and UC Davis teams decode attempted speech at conversational rates from motor cortex, with large vocabularies and single-digit word error rates in the best case." }, { "year": "2023", "title": "Brain–spine interface", "text": "A Lausanne team restores volitional walking in a man with spinal cord injury by linking a cortical implant to an epidural spinal stimulator." }, { "year": "2023", "title": "Brain-spine interface", "text": "A Lausanne team restores volitional walking in a man with spinal cord injury by linking a cortical implant to an epidural spinal stimulator." }, { "year": "2024–2026", "title": "Commercial implants enter trials", "text": "Neuralink, Synchron, Precision Neuroscience, Paradromics, and several Chinese groups run early feasibility studies; none has regulatory approval for routine use." } { "year": "2024-2026", "title": "Commercial implants enter trials", "text": "Neuralink, Synchron, Precision Neuroscience, Paradromics, and several Chinese groups run early feasibility studies; none has regulatory approval for routine use." }]]`````` lines 135–143 → 139–1473 unchanged lines not shown
**Cursor and device control.** People with tetraplegia can move a computer pointer, click, type on a**Cursor and device control.** People with tetraplegia can move a computer pointer, click, type on avirtual keyboard, and drive a robotic arm through several degrees of freedom.[^hochberg2006] Thevirtual keyboard, and drive a robotic arm through several degrees of freedom.[^hochberg2006] The2012 and 2013 robotic-arm reports, in which participants reached, grasped, and drank2012 and 2013 robotic-arm reports, in which participants reached, grasped, and drank unassisted,unassisted, remain the reference demonstrations.[^hochberg2012][^collinger2013] Performance in theremain the reference demonstrations.[^hochberg2012][^collinger2013] Performance in the bestbest participants approaches a slow but usable pointing device. The [[utah-array]] remains the mostparticipants approaches a slow but usable pointing device. The [[utah-array]] remains the mostcommon sensor for this work, and the multi-site BrainGate consortium has produced most of thecommon sensor for this work, and the multi-site BrainGate consortium has produced most of thelong-run data. A fully implanted surface-electrode system used at home by a person with late-stagelong-run data. A fully implanted surface-electrode system used at home by a person with late-stageALS demonstrated that the approach can survive outside a laboratory.[^vansteensel2016]ALS demonstrated that the approach can survive outside a laboratory.[^vansteensel2016]lines 158–172 → 162–17614 unchanged lines not shown
([[neuralink]], Paradromics, Blackrock Neurotech), thin-film surface arrays ([[ecog-interfaces]],([[neuralink]], Paradromics, Blackrock Neurotech), thin-film surface arrays ([[ecog-interfaces]],Precision Neuroscience), and endovascular electrodes threaded through a vein ([[stentrode]],Precision Neuroscience), and endovascular electrodes threaded through a vein ([[stentrode]],developed by [[synchron]]). Each trades bandwidth against surgical risk. Several Chinese academicdeveloped by [[synchron]]). Each trades bandwidth against surgical risk. Several Chinese academicand state-backed groups have also reported implants in participants since 2024, though publicand state-backed groups have also reported implants in participants since 2024, though public detaildetail is limited and independent verification scarce.is limited and independent verification scarce. What has not been demonstrated is equally worth stating. No BCI has restored a rich sense of touch;No BCI has restored a rich sense of touch; the best feedback so far is a small number ofthe best feedback so far is a small number of discriminable pressure percepts delivered bydiscriminable pressure percepts delivered by intracortical or peripheral stimulation, well short ofintracortical or peripheral stimulation, well short of what a hand needs. No system has restoredwhat a hand needs. No system has restored memory in a clinically meaningful way, despite thememory in a clinically meaningful way, despite the encoding-model work described underencoding-model work described under [[memory-prosthesis]]. Nor has any implanted BCI been shown to[[memory-prosthesis]]. And no implanted BCI has been shown to improve any capability in a healthyimprove any capability in a healthy person, which is the premise on which most enhancement-orientedperson, which is the premise on which most enhancement-oriented interest rests.interest rests. > [!caution] Sample sizes are tiny> [!caution] Sample sizes are tiny> The headline results in this field typically come from one to four participants, often the same> The headline results in this field typically come from one to four participants, often the samelines 177–259 → 181–2624 unchanged lines not shown
## The bandwidth problem## The bandwidth problem Popular framing treats BCI progress as an electrode-count race, on the assumption that informationPopular framing treats BCI progress as an electrode-count race, on the assumption that informationtransfer scales with channels. It does not scale cleanly. Motor cortical activity during reachingtransfer scales with channels. It does not scale cleanly. Motor cortical activity during reaching isis well described by a low-dimensional dynamical structure — a neural manifold — in which a fewwell described by a low-dimensional dynamical structure (a neural manifold) in which a few dozendozen latent dimensions capture most of the variance.[^gallego2017] Adding electrodes samples that same structurelatent dimensions capture most of the variance.[^gallego2017] Adding electrodes samples that samemore densely rather than revealing new independent signals, so returns diminish. This is why astructure more densely rather than revealing new independent signals, so returns diminish. This is96-channel array from the 1990s can support performance comparable to systems with ten times thewhy a 96-channel array from the 1990s can support performance comparable to systems with ten timeschannels, and why decoder architecture has mattered more than sensor count.the channels, and why decoder architecture has mattered more than sensor count. Where more channels do help is coverage: sampling several cortical areas, or sampling a functionalWhere more channels do help is coverage: sampling several cortical areas, or sampling a functionalmap finely enough to separate articulators in speech cortex. The genuinely hard constraints aremap finely enough to separate articulators in speech cortex. The hard constraints lie elsewhere: theelsewhere — the number of independent control dimensions a person can learn to modulate, thenumber of independent control dimensions a person can learn to modulate, the non-stationarity of thenon-stationarity of the recorded population from day to day, and the near-total absence of arecorded population from day to day, and the near-total absence of a high-resolution write channel.high-resolution write channel. Reading intention out is a solved-enough problem for manyReading intention out is a solved-enough problem for many applications; writing rich sensoryapplications; writing rich sensory information in is not, which is why touch feedback ininformation in is not, which is why touch feedback in [[neuroprosthetics]] remains crude compared[[neuroprosthetics]] remains crude compared with motor decoding. One laboratory response is to makewith motor decoding. One laboratory response is to make the stimulating hardware itself spike like athe stimulating hardware itself spike like a neuron, at biological voltages and timescales; suchneuron, at biological voltages and timescales; such[[artificial-neurons|bio-interfacing artificial neurons]] have so far driven living neurons only in[[artificial-neurons|bio-interfacing artificial neurons]] have so far driven living neurons only inacute experiments, such as slices of mouse cerebellum.[^hadke2026]acute experiments, such as slices of mouse cerebellum.[^hadke2026] ## Limitations## Limitations Implanted arrays lose channels. The brain mounts a foreign-body response — microglial activation,Implanted arrays lose channels. The brain mounts a foreign-body response (microglial activation,astrocytic encapsulation — that displaces neurons from the recording tip, while insulation andastrocytic encapsulation) that displaces neurons from the recording tip, while insulation and metalmetal traces degrade in a warm saline environment. Signal yield typically declines over months totraces degrade in a warm saline environment. Signal yield typically declines over months to years,years, though some implants have supported usable control beyond a thousand days and a few forthough some implants have supported usable control beyond a thousand days and a few for severalseveral years; the failure statistics are set out under [[utah-array]].years; the failure statistics are set out under [[utah-array]]. Percutaneous connectors, still standard in academic systems, carry infection risk and tether thePercutaneous connectors, still standard in academic systems, carry infection risk and tether theuser to a lab. Fully implanted wireless systems solve this but constrain power and data rate; theuser to a lab. Fully implanted wireless systems solve this but constrain power and data rate; themost aggressive proposal for removing the tether, untethered ultrasonic motes, is covered undermost aggressive proposal for removing the tether, untethered ultrasonic motes, is covered under[[neural-dust]] and has no human results.[[neural-dust]] and has no human results. Decoders drift, requiring recalibration that ranges fromDecoders drift, requiring recalibration that ranges from minutes daily to occasional, depending onminutes daily to occasional, depending on the system. Almost all reported performance comes fromthe system. Almost all reported performance comes from controlled settings with a techniciancontrolled settings with a technician present.present. There is also a structural risk specific to commercial neurotechnology: a company can fail whileThere is also a structural risk specific to commercial neurotechnology: a company can fail while itsits devices remain in people's heads. The discontinuation of the Argus II retinal system left usersdevices remain in people's heads. The discontinuation of the Argus II retinal system left users withwith unsupported implants, a precedent that shadows every BCI trial. See [[retinal-implant]].unsupported implants, a precedent that shadows every BCI trial. See [[retinal-implant]]. ## Ethics and governance## Ethics and governance Implanted BCIs raise questions that older neurotechnology such as [[deep-brain-stimulation]] andImplanted BCIs raise questions that older neurotechnology such as [[deep-brain-stimulation]] and thethe [[cochlear-implant]] introduced in milder form: who owns the neural data, what happens when a[[cochlear-implant]] introduced in milder form: who owns the neural data, what happens when adecoder misreads intent, and whether a device that shapes behaviour compromises agency. Thedecoder misreads intent, and whether a device that shapes behaviour compromises agency. The specificspecific novelty is that recorded activity can support inferences the user did not intend tonovelty is that recorded activity can support inferences the user did not intend to disclose, andisclose, an issue taken up under [[mental-privacy]]. Legislatures have begun responding —issue taken up under [[mental-privacy]]. Legislatures have begun responding under the banner ofconstitutional and state-level neural-data provisions exist in several jurisdictions — under the[[neurorights]], and constitutional and state-level neural-data provisions exist in severalbanner of [[neurorights]], though enforcement mechanisms remain thin.jurisdictions, though enforcement mechanisms remain thin. Consumer neurotechnology is a separate regulatory category and a much weaker technical one.Consumer neurotechnology is a separate regulatory category and a much weaker technical one. WearableWearable EEG headsets and [[non-invasive-neuromodulation]] devices are sold for attention training,EEG headsets and [[non-invasive-neuromodulation]] devices are sold for attention training, sleep,sleep, and gaming with evidence that ranges from thin to absent, and the "brain-reading" claimsand gaming with evidence that ranges from thin to absent, and the "brain-reading" claims attached toattached to them substantially outrun what scalp electrodes can resolve. Regulators have generallythem substantially outrun what scalp electrodes can resolve. Regulators have generally treated thesetreated these as wellness products rather than medical devices, the same line that governsas wellness products rather than medical devices, the same line that governs[[wearable-health-sensors]], which is why the emerging neural-data statutes target data handling[[wearable-health-sensors]], which is why the emerging neural-data statutes target data handlingrather than efficacy claims.rather than efficacy claims. > [!debate] How invasive is worth it> [!debate] How invasive is worth it> Synchron's position is that a device delivered by catheter, with sixteen electrodes, will reach> Synchron's position is that a device delivered by catheter, with sixteen electrodes, will reach> far more patients than one requiring a craniotomy, and that discrete reliable control is enough> far more patients than one requiring a craniotomy, and that discrete reliable control is enough> for most assistive tasks. The counter-position, taken by the penetrating-array developers, is> for most assistive tasks. The counter-position, taken by the penetrating-array developers, is that> that low-bandwidth control caps the addressable applications at switch-like interaction and rules> low-bandwidth control caps the addressable applications at switch-like interaction and rules out> out speech and dexterous limb control. Both claims are testable and neither has been settled.> speech and dexterous limb control. Both claims are testable and neither has been settled. ## Outlook## Outlook The near-term agenda is legible: more participants, wireless and fully implanted systems, decodersThe near-term agenda is clear: more participants, wireless and fully implanted systems, decodersintended to survive a week without recalibration, and eventually a pivotal trial in a well-definedintended to survive a week without recalibration, and eventually a pivotal trial in a well-definedindication such as loss of speech in ALS. If that sequence holds, it could produce an approvedindication such as loss of speech in ALS. If that sequence holds, it could produce an approvedassistive device for a small clinical population, though no timeline for it is well supported andassistive device for a small clinical population, though no timeline for it is well supported andnone of the current studies is large enough to predict one.none of the current studies is large enough to predict one. The longer-term claims — that BCIs will serve as a general-purpose channel forLonger-term claims rest on assumptions the clinical work does not test: that BCIs will serve as a[[human-ai-merger]], or provide the read-out fidelity that [[whole-brain-emulation]] would requiregeneral-purpose channel for [[human-ai-merger]], or provide the read-out fidelity that— rest on assumptions the clinical work does not test. A speech decoder recovers a motor plan, not[[whole-brain-emulation]] would require. A speech decoder recovers a motor plan, not a thought; aa thought; a 1,024-channel array samples a millionth of a cortical hemisphere. Whether elective1,024-channel array samples a millionth of a cortical hemisphere. Whether elective implantation inimplantation in healthy people ever clears the risk-benefit bar is a question about surgicalhealthy people ever clears the risk-benefit bar is a question about surgical complication rates andcomplication rates and device lifetimes, and neither is currently known well enough to answer.device lifetimes, and neither is currently known well enough to answer. ## See also## See also removed, struck through added, underlinedLine numbers count the serialised markdown of each revision, frontmatter included.
200 lines are the same in both revisions, and 93 of them are not shown. Neither revision here is necessarily the current article — read Brain–computer interface for the text this wiki stands behind today.